DSC-OIT-400

[vc_row][vc_column][vc_column_text]

DSC-OIT-400

Model: DSC-OIT-400
Machine weight: 35 kg
Dimensions of the device: L * W * H 500 * 350 * 250 (mm)
  • Temperature range: 25 to 400 degrees Celsius
  • Temperature rate: (1-40) c / min
  • Accuracy of temperature measurement -1.1 ° C
  • Accuracy of measuring the amount of energy + 0.001 + + mW
  • Determination of enthalpy / melting temperature / crystallization temperature / glass transition temperature / OIT time / temperature specific heat value
  • Ability to increase the auto-scale of axes (Auto Scale)
  • Ability to control the temperature gradient through the software
  • Ability to calibrate the software of the device simply by the laboratory operator
  • Data sampling and storage of calibration temperature display data and oxidation induction processing time

[/vc_column_text][vc_separator color=”juicy_pink” style=”shadow” border_width=”5″][/vc_column][/vc_row]

DSC-400

[vc_row][vc_column][vc_column_text]

Differential Scanning Calorimeter (DSC-400)

Model: DSC-400

Machine weight: 35 kg

Dimensions of the device: L * W * H 500 * 350 * 250 (mm)

  • Temperature range: 25 to 400 degrees Celsius
  • Temperature rate: (1-40) c / min
  • Accuracy of temperature measurement -1.1 ° C
  • Accuracy of measuring the amount of energy + 0.001 + + mW
  • Determination of enthalpy / melting temperature / crystallization temperature / glass transition temperature / OIT time / temperature specific heat value
  • Ability to increase the auto-scale of axes (Auto Scale)
  • Ability to control the temperature gradient through the software
  • Ability to calibrate the software of the device simply by the laboratory operator
  • Data sampling and storage of calibration temperature display data and oxidation induction processing time

[/vc_column_text][vc_separator color=”juicy_pink” style=”shadow” border_width=”5″][/vc_column][/vc_row]

DSC-1000

[vc_row][vc_column][vc_column_text]

Differential Scanning Calorimeter (DSC-1000)

Model: DSC-1000
Machine weight: 35 kg
Dimensions of the device: L * W * H 500 * 350 * 250 (mm)
  • Temperature range: 25 to 1000 degrees Celsius
  • Temperature rate: (1-40) c / min
  • Accuracy of temperature measurement -1.1 ° C
  • Accuracy of measuring the amount of energy + 0.001 + + mW
  • Determination of enthalpy / melting temperature / crystallization temperature / glass transition temperature / OIT time / temperature specific heat value
  • Ability to increase the auto-scale of axes (Auto Scale)
  • Ability to control the temperature gradient through the software
  • Ability to calibrate the device software simply by the laboratory operator
  • Data sampling and storage of calibration temperature display data and oxidation induction processing time

[/vc_column_text][vc_separator color=”juicy_pink” style=”shadow” border_width=”5″][/vc_column][/vc_row]

DSC-600-Ci

[vc_row][vc_column][vc_column_text]

Differential Scanning Calorimeter (DSC-600-Ci)

Model: DSC-600-Ci
Machine weight: 35 kg
Dimensions of the device: L * W * H 500 * 350 * 250 (mm)
  • Temperature range: -100 to 600 degrees Celsius
  • Temperature rate: (1-40) c / min
  • Temperature measurement accuracy -1.1 ° C
  • Accuracy of energy measurement + 0.001 + + MW
  • Determination of enthalpy / melting temperature / crystallization temperature / glass transition temperature / OIT time / specific heat value
  • Ability to increase the automatic scale of axes (automatic scale)
  • Ability to control the temperature gradient through the software
  • Ability to calibrate the device software simply by the lab operator
  • Sampling and storage data display calibration temperature data and oxidation induction processing time

[/vc_column_text][vc_separator color=”juicy_pink” style=”shadow” border_width=”5″][/vc_column][/vc_row]

DSC-400-Ci

[vc_row][vc_column][vc_column_text]

Differential Scanning Calorimeter (DSC-400-Ci)

Model: DSC-400-Ci
Machine weight: 35 kg
Dimensions of the device: L * W * H 500 * 350 * 250 (mm)
  • Temperature range: 100_ up to 400 degrees Celsius
  • Temperature rate: (1-40) c / min
  • Accuracy of temperature measurement -1.1 ° C
  • Accuracy of measuring the amount of energy + 0.001 + + mW
  • Determination of enthalpy / melting temperature / crystallization temperature / glass transition temperature / OIT time / temperature specific heat value
  • Ability to increase the auto-scale of axes (Auto Scale)
  • Ability to control the temperature gradient through the software
  • Ability to calibrate the device software simply by the laboratory operator
  • Data sampling and storage of calibration temperature display data and oxidation induction processing time

[/vc_column_text][vc_separator color=”juicy_pink” style=”shadow” border_width=”5″][/vc_column][/vc_row]