[vc_row][vc_column][vc_column_text]

DSC-OIT-400

Model: DSC-OIT-400
Machine weight: 35 kg
Dimensions of the device: L * W * H 500 * 350 * 250 (mm)
  • Temperature range: 25 to 400 degrees Celsius
  • Temperature rate: (1-40) c / min
  • Accuracy of temperature measurement -1.1 ° C
  • Accuracy of measuring the amount of energy + 0.001 + + mW
  • Determination of enthalpy / melting temperature / crystallization temperature / glass transition temperature / OIT time / temperature specific heat value
  • Ability to increase the auto-scale of axes (Auto Scale)
  • Ability to control the temperature gradient through the software
  • Ability to calibrate the software of the device simply by the laboratory operator
  • Data sampling and storage of calibration temperature display data and oxidation induction processing time

[/vc_column_text][vc_separator color=”juicy_pink” style=”shadow” border_width=”5″][/vc_column][/vc_row]

DSC-400

[vc_row][vc_column][vc_column_text]

Differential Scanning Calorimeter (DSC-400)

Model: DSC-400

Machine weight: 35 kg

Dimensions of the device: L * W * H 500 * 350 * 250 (mm)

  • Temperature range: 25 to 400 degrees Celsius
  • Temperature rate: (1-40) c / min
  • Accuracy of temperature measurement -1.1 ° C
  • Accuracy of measuring the amount of energy + 0.001 + + mW
  • Determination of enthalpy / melting temperature / crystallization temperature / glass transition temperature / OIT time / temperature specific heat value
  • Ability to increase the auto-scale of axes (Auto Scale)
  • Ability to control the temperature gradient through the software
  • Ability to calibrate the software of the device simply by the laboratory operator
  • Data sampling and storage of calibration temperature display data and oxidation induction processing time

[/vc_column_text][vc_separator color=”juicy_pink” style=”shadow” border_width=”5″][/vc_column][/vc_row]

DSC

[vc_row][vc_column][vc_column_text]

DSC

About analysis

DSC analysis: DSC differential scanning calorimeter analysis

DSC analysis is used to investigate thermal behavior. This analysis can determine the temperature and heat of phase change (melting, change in crystal structure, etc.) and chemical changes (decomposition, oxidation, etc.). DSC analysis, like DTA, is an analysis to determine the physical-thermal behavior of materials and can be used to obtain the physical properties of the material such as melting temperature, evaporation temperature and other phase changes of materials such as crystal deformation temperature or as a chemical-thermal analysis Obtain the decomposition or oxidation temperature of the material

The advantage of DSC analysis over DTA analysis is that in this analysis, in addition to the temperature of transformations or reactions, the heat generated or absorbed can also be determined. In the DSC test, a comparison between two samples of the rate of transformations or chemical changes can also be qualitatively compared

Technical specifications of DSC analysis

Heating rate: from 1 to 20 degrees Celsius per minute

Gases used: argon, air and nitrogen

Temperature process and cooling cycle up to room temperature

Operating temperature range: ambient temperature up to 1000 degrees

Flexible and adaptable calibration

Minimum sample weight 20 mg (at least 50 mg of sample is required to measure gross samples or samples with high molecular weight)

High resolution to measure very fast changes and close events

Ability to perform the same temperature process and cooling cycle to room temperature

Abilities DSC Analysis

Identify the components of alloys as well as raw materials such as the explanation of PE80 from PE100 as well as the thermal analysis of a wide range of materials such as cosmetics, food; Pharmaceuticals, textiles and

Study of processes such as: melting / crystallization behavior, crosslinking reaction, structure decomposition, purification and

Measure the difference in heat flow between the sample and the reference

Calculate the level below the enthalpy, temperature and time diagram

Determination of thermal properties of epoxy powders and coatings according to the standard of protective polyethylene coating of steel pipes

Crystallization analysis, moisture analysis, reverse failure analysis

Reverse Engineering

Approve the process

Identify contaminants

Specifications of DSC analysis sample

Sample weight should be at least 20 mg and at most 0.1 g

Non-powdered samples should not be larger than 2 mm

The sample should not contain compounds that can explode or produce strong gas, so the overall chemical composition of the sample should be known

The heating rate, maximum temperature and sample composition must be specified by the applicant

The analysis price depends on the specified temperature range and the cream rate can vary

The device software does not have the ability to determine the Tg point and other points in this test and applicants must obtain it themselves

Results of analysis and interpretation of DSC analysis

The analysis results are presented as a PDF file and an EXCEL file. The PDF file shows the test result in the form of a graph with test specifications. The EXCEL file contains device specifications, test conditions and point-to-point data related to the analysis chart. Using this point-to-point data, the analysis chart can be drawn in different software and the diagram and thermal behavior of the material can be studied

[/vc_column_text][vc_separator color=”juicy_pink” style=”shadow” border_width=”5″][/vc_column][/vc_row]

Aluminum and ceramic pens

[vc_row][vc_column][vc_column_text]

Aluminum and ceramic pens

Model: SCR

  • For TGA – DSC – STA tests
  • High purity and high temperature resistant
  • In different dimensions with and without cap

[/vc_column_text][vc_separator color=”juicy_pink” style=”shadow” border_width=”5″][/vc_column][/vc_row]

Reactor

[vc_row][vc_column][vc_column_text]

Laboratory Pressure Reactor

Model: Reactor

  • With a cylinder volume of 1 liter to 25 liters
  • It has two corrosion-resistant inlet and outlet valves
  • With load pressure up to 400 bar
  • Has HMI
  • Has a control system
  • Has a pressure sensor
  • Ability to display cylinder pressure
  • Ability to display test time with an accuracy of 1 second

 

[/vc_column_text][vc_separator color=”juicy_pink” style=”shadow” border_width=”5″][/vc_column][/vc_row]

DMTA-1000

[vc_row][vc_column][vc_column_text]

Thermomeechanical Analysis (DMTA-1000)

Model: DMTA-1000

  • Ambient temperature range C º 25 to C º1000
  • Changes in the dimensions or mechanical properties of the sample
  • Ambient temperature range C º 25 to C º 1000
  • Force range N 001 to N10
  • Contains calibration reference material (iron)
  • Holds a calibration certificate with the approval of the standard office (only the holder of the certificate of approval of the standard office)
  • Heat rate: (0.1 – 80) min / C º
  • Accuracy of temperature measurement 1 1 degree Celsius
  • Accuracy of force measurement: N 001 ±
  • Has a fan for cooling
  • Air cooling system
  • Softening temperature
  • Determination of glass temperature
  • melting point
  • Change the dimensions of the material
  • Thermal expansion
  • Quaternary glass probe
  • Determination of longitudinal expansion coefficient

[/vc_column_text][vc_separator color=”juicy_pink” style=”shadow” border_width=”5″][/vc_column][/vc_row]

STA

[vc_row][vc_column][vc_column_text]

Simultaneous Thermal Analysis (STA)

 

 

Model: STA

Machine weight: 50 kg

Dimensions of the device: L * W * H 500 * 380 * 310 (mm)

  • Temperature range: 25 to 1000 degrees Celsius
  • Temperature and enthalpy sensor made of high precision platinum
  • Temperature range: room temperature up to 1000 degrees Celsius
  • Heating rate: c / min (0.1-50)
  • Ability to increase the auto-scale of axes (Auto Scale)
  • Temperature measurement accuracy of 0.1 + _ degrees Celsius
  • Enthalpy determination – Melting temperature – Crystallization temperature – Glass transfer temperature – OIT time – Specific heat value temperature
  • Mass measurement range: 1mg ~ 10g
  • Ability to perform TGA-DSC simultaneous testing

[/vc_column_text][vc_separator color=”juicy_pink” style=”shadow” border_width=”5″][/vc_column][/vc_row]

TGA

[vc_row][vc_column][vc_column_text]

Thermogravimetric Analysis (TGA)

Model: TGA

Machine weight: 45 kg

Dimensions of the device: L * W * H 500 * 350 * 700 (mm)

  • Temperature range: 25 to 1000 degrees Celsius
  • Temperature measurement accuracy: 0.1 + _ degrees Celsius
  • Accuracy of energy measurement: 0.001 + _ mW
  • Weight measurement accuracy: 0.001 g
  • Made according to ISO 11358
  • Digital flow control of the device by the software along with the flow display on the software
  • Data sampling and data storage Melting point display temperature display

[/vc_column_text][vc_separator color=”juicy_pink” style=”shadow” border_width=”5″][/vc_column][/vc_row]

DSC-1000

[vc_row][vc_column][vc_column_text]

Differential Scanning Calorimeter (DSC-1000)

Model: DSC-1000
Machine weight: 35 kg
Dimensions of the device: L * W * H 500 * 350 * 250 (mm)
  • Temperature range: 25 to 1000 degrees Celsius
  • Temperature rate: (1-40) c / min
  • Accuracy of temperature measurement -1.1 ° C
  • Accuracy of measuring the amount of energy + 0.001 + + mW
  • Determination of enthalpy / melting temperature / crystallization temperature / glass transition temperature / OIT time / temperature specific heat value
  • Ability to increase the auto-scale of axes (Auto Scale)
  • Ability to control the temperature gradient through the software
  • Ability to calibrate the device software simply by the laboratory operator
  • Data sampling and storage of calibration temperature display data and oxidation induction processing time

[/vc_column_text][vc_separator color=”juicy_pink” style=”shadow” border_width=”5″][/vc_column][/vc_row]

DSC-600-Ci

[vc_row][vc_column][vc_column_text]

Differential Scanning Calorimeter (DSC-600-Ci)

Model: DSC-600-Ci
Machine weight: 35 kg
Dimensions of the device: L * W * H 500 * 350 * 250 (mm)
  • Temperature range: -100 to 600 degrees Celsius
  • Temperature rate: (1-40) c / min
  • Temperature measurement accuracy -1.1 ° C
  • Accuracy of energy measurement + 0.001 + + MW
  • Determination of enthalpy / melting temperature / crystallization temperature / glass transition temperature / OIT time / specific heat value
  • Ability to increase the automatic scale of axes (automatic scale)
  • Ability to control the temperature gradient through the software
  • Ability to calibrate the device software simply by the lab operator
  • Sampling and storage data display calibration temperature data and oxidation induction processing time

[/vc_column_text][vc_separator color=”juicy_pink” style=”shadow” border_width=”5″][/vc_column][/vc_row]